The DTCT-EdgeN modular micro network room all-in-one series products are characterized by safety, stability, reliability, flexibility, and efficient integration; one all-in-one machine serves as a network room, providing a safe, reliable, intelligent management, and energy-saving operating space and environment for information equipment.
PRODUCT FEATURES
产品特点
PRODUCT FEATURES
01
Integrated & Efficient
Integrated design. UPS, air conditioning, power distribution and monitoring are pre-installed in factory for plug-and-play deployment on site

02
Ultra-high Computing Density
Wide voltage and wide temperature range operation, suitable for harsh environments such as unstable power grid, high temperature and high humidity

03
Simplified O&M
Remote intelligent monitoring, unattended operation and proactive fault warning to cut O&M costs

04
High-density Mini Integration
Compact footprint, flexible deployment in confined spaces such as corridors, weak-current shafts and basements

产品优势
PRODUCT ADVANTAGES
PRODUCT ADVANTAGES
Construction Period
Footprint
Equipment Integration
Compatibility
Energy Saving
Operation
After-sales Maintenance
Modular Data All-in-One Unit

Within 7 Days

Modular rack-mounted deployment, highly integrated to reduce floor space

One-stop supply, pre-integration, all-in-one design and unified management

Factory pre-integration, pre-commissioning and overall testing with high compatibility

Built-in rack air conditioner only cools in-cabinet equipment, saving over 50% energy compared with traditional solutions

Fully enclosed cabinet operation with double-layer hollow glass for high cleanliness and stable performance

Unified maintenance with multi-level service plans; supports 7×24 unattended operation to reduce O&M costs
Traditional Computer Room
After-sales Maintenance
Subsystems including UPS, air conditioners and cabinets require separate spaces
Multi-vendor supply, separate construction and independent management
Integration of multi-brand products leads to complicated commissioning and poor compatibility
PUE ranges from 2.0 to 3.0 with low cooling utilization
Prone to dust accumulation, impairing stable operation and shortening equipment service life
Multiple maintenance providers, ambiguous accountability for related faults and slow response
PRODUCT ADVANTAGES
产品参数
PRODUCT ADVANTAGES
| EN-C Type Standalone Unit | |||
| EN-C Standalone Unit | Without Environmental Monitoring | With Environmental Monitoring, No Operation Screen | With Environmental Monitoring & Operation Touch Screen |
| Dimensions | 600*800*1200mm | 600*800*1600mm | 600*800*2000mm |
| Cooling System | Total Heat Exchange Module | ||
| Power Distribution System | 1 x 8-port Rack-mounted PDU as standard | ||
| Integrated Monitoring System | / | Supports power & environmental monitoring; cabinet temperature and total heat exchange module can be monitored | Supports power & environmental monitoring; cabinet temperature and total heat exchange module can be monitored, with local operation touch screen as standard |
| Backup Time | 15min~240min configured on demand | ||
| Available Equipment Space | ≥ 18U | ≥ 28U | ≥ 38U |
| EN-D Type Standalone Unit | |||
| EN-D Standalone Unit | Without Environmental Monitoring | With Environmental Monitoring, No Operation Screen | With Environmental Monitoring & Operation Touch Screen |
| Dimensions | 600*1000*2000mm | ||
| Cooling System | Outdoor-unit-free cooling module: 1.5kW, 2.5kW | ||
| Power Distribution System | 1 x 8-port Rack-mounted PDU as standard | ||
| Integrated Monitoring System | / | Supports power & environmental monitoring; air conditioner, water leakage, temperature & humidity and smoke detector can be monitored | Supports power & environmental monitoring; air conditioner, water leakage, temperature & humidity and smoke detector can be monitored, with local operation touch screen as standard |
| Backup Time | 15min~240min configured on demand | ||
| Available Equipment Space | ≥ 30U | ||
| ▋ Six Major Functions | ● Fusion Analysis ● Comprehensive Monitoring ● Topology Management ● Unified Management ● Asset Management ● Auxiliary Management |
|
| ▋ Five Core Advantages | Centralized Control | Centralized management of multiple all-in-one units |
| Diversified Monitoring | Multiple monitoring modes including large screen, list and 3D view | |
| Real-time Monitoring | Full-screen dynamic display of real-time data and alarms of computer room | |
| Green Product Design | Supports computer room energy consumption management and PUE display | |
| Systematic Management | Supports access control and video management; flexible multi-level alarm linkage configuration | |
| ▋ Touch Screen | Real-time environmental monitoring data displayed on the touch screen of all-in-one unit Allows users to view device data intuitively Administrators can quickly assess the computer room operating status via the touch screen |
|