DTCT InduX Intelligent Core Branch Computer Room Integrated Machine
DTCT-InduX Smart Core Branch and Sub-branch Computer Room All-in-One Machine
DTCT-InduX Smart Core Branch and Sub-branch Computer Room All-in-One Machine
PRODUCT OVERVIEW
PRODUCT OVERVIEW
The DTCT-InduX intelligent core branch and sub-branch machine room all-in-one device represents the mainstream trend in the construction of machine rooms for banking institutions at all levels. It facilitates the sharing of space and energy between technology and security machine rooms, while maintaining isolation between management and usage. The device features functional partitions for network equipment, monitoring equipment, and alarm equipment, enhancing the level of bank information security. It empowers banks with technology, reduces consumption, increases efficiency, and promotes refined management.
PRODUCT FEATURES
PRODUCT FEATURES
01
Efficient Integration
High-reliability power supply & distribution architecture with dual-input and UPS backup power to ensure 7×24-hour uninterrupted core business operation

02
Stable & Reliable
Silent design friendly to office environment; exquisite appearance matching the professional image of banking industry

03
Simplified O&M
Integrated intelligent access control, video surveillance and environmental sensing to meet security compliance requirements

04
High-density Micro Integration
Modular rapid deployment enables zero waiting for branch opening and renovation projects

产品优势
PRODUCT ADVANTAGES
PRODUCT ADVANTAGES
Construction Period
Space Occupation
Equipment Integration
Compatibility
Energy Saving
Operation
After-sales Maintenance
Modular Data All-in-one Machine

Within 7 Days

Modular rack deployment, highly integrated, reduces computer room footprint

One-stop supply, pre-integrated, all-in-one, unified management

Factory pre-integration, pre-commissioning and full testing with high compatibility

Built-in rack air conditioner only cools in-cabinet equipment, saving over 50% energy compared with traditional solutions

Fully enclosed cabinet operation, double-layer hollow glass, high cleanliness and stable operation

Unified maintenance with multi-level service plans; supports 7×24 unattended operation to cut O&M costs
Traditional Computer Room
After-sales Maintenance
Subsystems such as UPS, air conditioners and cabinets require separate spaces
Multi-supplier sourcing, separate construction and independent management
Integration of products from multiple vendors leads to complex commissioning and poor compatibility
PUE ranges from 2.0 to 3.0 with low cooling utilization
Prone to dust accumulation, which impairs stable operation and shortens equipment service life
Maintained by multiple vendors; unclear responsibility and delayed response for correlated faults
PRODUCT SPECIFICATIONS
PRODUCT SPECIFICATIONS
| DTCT-InduX Zhihe Branch Computer Room All-in-one Machine | ||
| DTCT-BankMod Zhihe Branch Computer Room All-in-one Machine | 3-Cabinet Unit | 7-Cabinet Unit |
| Dimension Specification | 1800mm*1000mm*2000mm | 4600mm*1000mm*2000mm |
| Cooling System | Max cooling capacity 4kW, air-cooled | Max cooling capacity 8kW*2, air-cooled |
| Power Distribution System | Max 10kVA/9kW; mains and UPS power distribution for low-voltage intelligent facilities inside the branch, including power supply for counter and computer room equipment | Max 2 units of 10kVA/9kW; mains and UPS power distribution for low-voltage intelligent facilities inside the branch, including power supply for counter and computer room equipment |
| Power per Cabinet | ≤3kW | |
| Integrated Monitoring System | Temperature & humidity, smoke detection, water leakage detection, air conditioner, power distribution, UPS and lead-acid battery monitoring | Temperature & humidity, smoke detection, water leakage detection, air conditioner, power distribution, UPS, lead-acid battery monitoring, front door fingerprint lock |
| Backup Time | 15min~240min configured according to actual requirements | |
| Available Equipment Space | ≥70U | ≥154U |
| ▋ Six Major Functions | ● Fusion Analysis ● Comprehensive Monitoring ● Topology Management ● Unified Management ● Asset Management ● Auxiliary Management |
|
| ▋ Five Major Advantages | Centralized Control | Centralized management of multiple all-in-one machines |
| Diversified Monitoring | Multiple monitoring modes including large-screen mode, list mode and 3D mode | |
| Real-time Monitoring | Full-screen dynamic display of real-time computer room monitoring data and alarm data | |
| Green Product Design | Supports computer room energy consumption management and PUE display | |
| Systematic Management | Supports access control and video management; flexible multi-level alarm configuration for alarm linkage | |
| ▋ Touch Screen | Dynamic environment monitoring data is synchronously displayed on the all-in-one machine touch screen Allows users to view device data intuitively Administrators can judge the computer room operating status immediately via the touch screen |
|